meu-icon

Kingsman 60” SERENE ZCVRB DIRECT VENT LINEAR GAS FIREPLACE

Kingsman

Item #:

  • $5,30900

Estimated Arrival: Between Dec 26 and Jan 02. * ETA for US orders only.

Shipping & Returns: Free Shipping. Free Returns on damaged items.


Kingsman 60” SERENE ZCVRB DIRECT VENT LINEAR GAS FIREPLACE

STANDARD FEATURES

  • Hi/Low Millivolt or IPI valve system will operate during power failures
  • Decorative Bronze Glass
  • Mobile Home, Bedroom and Bed Sitting Room approved
  • Safety Screen Barrier

OPTIONAL FEATURES

SURROUND

Stainless Steel or Black

FAN KIT

Heat activated with variable speed control

UNIVERSAL LIGHT KIT

Accent Lighting – Halogen Lamps

WALL MOUNT THERMOSTAT

Standard On/Off or Programmable 5 day (weekday) and 2 day (weekend)

LINER

Porcelain Reflective

MEDIA OPTIONS

Multi-Colored Cannonballs

REMOTE CONTROL

On/Off, Thermostat On/Off, Thermostat On/Off modulating, Thermostat On/Off modulating and fan control

ENCLOSURE GRILL

Front – ZCVRB47 46 3/4” W x 2 5/8” H
Front – ZCVRB60 60 5/8” W x 3 5/8” H
Sides – ZCVRB47/60 15 1/4” W x 6 5/8” H

Model     ZCVRB60LP/LPE      ZCVRB60N/NE

Fuel         Propane                    Natural
Flue         Top                            Top
Gas Control  Millivolt / IPI        Millivolt / IPI
Input Max.   35,000 BTU   35,000 BTU
Input Min.   28,000 BTU   23,000 BTU
FE (p.4.1-02)%  55.27% / 56.66%  55.27% / 56.66%
Venting  5"Flex or8"Hard Pipe 5"Flex or8"Hard Pipe
Viewing Area  40 5/8” x 13 7/8”   40 5/8” x 13 7/8”
Glass Type  Tempered   Tempered

Certification   Heater   Heater

Actual Width (CVCK)  46 5/8”  46 5/8”
Actual Height (CVCK)  38 5/8”   38 5/8”
Actual Depth (CVCK)  17 3/4”  17 3/4”
Power Vent Yes  Yes

Vented Chase Option

The chase of the appliance may be vented to achieve Cool Touch Walls or reduced Mantel Clearances. The following options are available to vent the chase:

  • The top of the chase can be left open.
  • A grill can be installed on the front of the chase.
  • If the chase bumps out into the room, side grills can be installed on each side of the chase.

Minimum enclosure height for a vented chase is measured from bottom of fireplace, ventilation of minimum free air opening is required. Choose between our Enclosure Grills (Front or Sides) or Custom Grill (if custom grills are used the louvers cannot slope) or adequate ventilation opening as stated in the manual. Grill or opening must meet minimum (as specified in the installation manual) of chase top/ceiling.

SPECIFICATIONS WITH OPENINGS (MIN. NO GRILLS)
ZCVRB47 – 105 sq/in.
ZCVRB60 – 200 sq/in.

Min. Enclosure Height
ZCVRB47 – 70”
ZCVRB60 – 76”

Min. Opening Below Ceiling
ZCVRB47 – 1-1/4”
ZCVRB60 – 1-7/8”

SPECIFICATIONS WITH GRILLS (MIN. AIR FREE OPENINGS)
ZCVRB47 – 105 sq/in.
ZCVRB60 – 220 sq/in.

Min. Enclosure Height
ZCVRB47 – 70”
ZCVRB60 – 76”

Grill Opening (Max. Distance from top of Ceiling)
ZCVRB47 – 2”
ZCVRB60 – 3/4”


dod

 


We Also Recommend